We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.
Home > UPS-FULLTECH
UPS works silently in the background—until heat becomes a problem—and common UPS failures are caused by overheating power modules, battery temperature rise, fan failure from long-term 24/7 operation, dust accumulation restricted ventilation, and low-quality replacement fans.
Why FULLTECH
Fulltech fans are available in IP55 and IP68 protection levels, providing strong resistance against dust, water, and salt spray. This enhanced protection ensures stable cooling performance even in harsh industrial conditions or environments with high humidity and airborne contaminants.
Fulltech designs specialized high-temperature fans to meet the demanding thermal requirements of UPS systems. These models maintain reliable operation even under elevated internal temperatures and are manufactured with insulation ratings of Class F and Class H, ensuring long-term durability under continuous load.
R/D Alarm function is suitable for equipment without built-in detection capability and can trigger a buzzer or LED to indicate abnormal fan operation.
F/G Tachometer output is designed for UPS systems or computers with integrated monitoring functions, allowing them to track fan speed and detect performance irregularities.
Built for Continuous 24/7 Operation
High durability bearings and reinforced motor design.

Strong Static Pressure

Stable airflow even inside compact UPS cabinets.

Longer Service Life
Ball-bearing and long-life bearing options designed for heavy-duty power equipment.
Low Noise & Low Vibration
Perfect for office/server room environments.

AC DC Models Available
110V / 220V AC, 12V / 24V / 48V DC options in stock. 

Ready Stock Fast Fulfillment
We keep popular sizes in stock
Product Range
High airflow and pressure for superior cooling , delivering over 30% performance boost with aviation-grade blades and stable 5000 RPM operation.

High-temperature and harsh-environment resistant, using Class B copper windings, 50,000-hour ball bearings, and UL94 V-0 flame-retardant housing.

Intelligent temperature and speed control , using an NTC sensor to match cooling output with heat load for lower noise and energy savings.

High IP rating, ensuring stable operation under heavy UPS loads and continuous high-demand working conditions.

Wide-voltage startup, supporting ±10% fluctuation to maintain reliable fan performance during UPS voltage shifts.
UPS Applications
Free & Professional Fan Selection Support
Free & Professional Fan Selection Support
You can tell us:
UPS brand & model
Fan size, airflow, pressure noise requirements
Get 1-on-1 technical advice within 24h
Compatibility check with Fulltech models
Why APAC FAN
Why APAC FAN
FULLTECH Partner FULLTECH Partner

We have direct access to the latest product information, priority availability of new fan models, and first-hand technical documentation. This partnership ensures that our customers receive accurate guidance and reliable product supply.

Shop Now
Rich Industry Expertise Rich Industry Expertise

Over the years, we have supported a wide range of UPS thermal management projects and have developed extensive insights into real-world challenges.

Shop Now
Extensive Inventory Extensive Inventory

We maintain regular stock of the most commonly used UPS fan sizes such as 80×80, 92×92, and 120×120, and we support scheduled supply planning for production lines.

Shop Now
Professional Support Professional Support

Our engineering support significantly simplifies the selection and replacement process for UPS clients. We assist with model matching based on airflow, static pressure, lifetime expectations, etc.

Shop Now
FAQ
Q1: Can FULLTECH fans replace my original UPS fan?
A1: Yes, FULLTECH fans are fully compatible with most mainstream UPS models and can directly replace original fans with proper selection.

Q2: What information do you need for fan selection?
A2: To recommend the most suitable UPS fan, please provide the following core information:
Original fan model (if available);
Key specifications: Voltage (e.g., 12V DC, 24V DC), airflow (e.g., 80 CFM), static pressure (e.g., 2.5 mmH₂O), noise level (e.g., 35 dB(A));
Physical dimensions: Length × width × height (e.g., 80×80×25 mm) and mounting hole spacing;
UPS brand, model, and power rating (e.g., 10kVA online UPS);
Special requirements: High-temperature resistance, dust-proof design, or long-life operation (e.g., 50,000 hours MTBF).

Q3: Do you support OEM/ODM services for UPS clients?
A3: Yes, we fully support OEM/ODM cooperation for UPS clients. Our customization capabilities include:Custom fan models, logos, and packaging;Tailored specifications (airflow, noise, voltage, dimensions) to match your UPS product design;Collaborative R D for special application scenarios (e.g., high-density UPS systems requiring low-noise, high-efficiency fans);Flexible production batches to meet both small-batch customization and large-scale mass production needs. Please contact our sales team to discuss your specific customization requirements.

Q4: How fast can you ship?
A4: Shipping speed depends on stock availability and your location.
For standard UPS fan models in stock: Same-day shipping.
For customized OEM/ODM orders: lead time varies by customization complexity and order quantity and we will provide a clear production and shipping timeline upon order confirmation.

Q5: Do you provide datasheets for FULLTECH UPS fans?
A5: Yes, we provide detailed technical datasheets for all UPS fan models. You can request the datasheet by contacting our sales team or downloading it directly from our official website/product page. For customized OEM/ODM products, we will provide tailored datasheets based on the final product specifications.
Still have questions? Contact Us