We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.
  • D2E146-HT67-01 ebm-papst
  • D2E146-HT67-01 ebm-papst
  • D2E146-HT67-01 ebm-papst
1/1
  • D2E146-HT67-01 ebm-papst
  • D2E146-HT67-01 ebm-papst
  • D2E146-HT67-01 ebm-papst

D2E146-HT67-01 ebm-papst

SKU:
5.0 (3)
83 Sold
$183.93 $0.00
ebm-papst,Centrifugal Fan 146mm,230V,355W,1060m³/h,460Pa,2610rpm,
Received successfully
Coupon Code
CONTINUE SHOPPING
Quantity:
0 in stock
Save More with Affordable Sea Freight, Talk to Our Experts Today!
Download
  • D2E146-HT67-01 ebm-papst
  • D2E146-HT67-01 ebm-papst
  • D2E146-HT67-01 ebm-papst
  • D2E146-HT67-01 ebm-papst
  • D2E146-HT67-01 ebm-papst
  • D2E146-HT67-01 ebm-papst
1/1
  • D2E146-HT67-01 ebm-papst
  • D2E146-HT67-01 ebm-papst
  • D2E146-HT67-01 ebm-papst
  • Description
  • Detailed Information
Brand: ebm-papst
Part No: D2E146-HT67-01
Fan Type: Centrifugal Fan
Rated Voltage(V): 230
Size(mm): 146
Max.Air Flow(m³/h): 1060
Max.Pressure(Pa): 460
Input Power(W): 355
Speed(rpm): 2610
Noise(dB): N/A

ebm-papst, as a well-known brand in the fan industry, is renowned for innovation and high quality. For many years, the brand has continuously invested in research and development, committed to providing efficient, energy-saving, and reliable fan products for global customers. Its products are widely used in various fields such as industry, commerce, and construction, and have established a good reputation in the industry. D2E146-HT67-01, as a centrifugal fan under ebm-papst, inherits the brand's excellent tradition and is the crystallization of technology and quality. It is designed to meet the ventilation needs of various complex working conditions, and can perform excellently in ventilation systems of large industrial plants or commercial buildings.

 

Interpretation of key parameters

 

Rated voltage (230V): The rated voltage is 230V, which indicates that the fan is suitable for common mains power supply environments. At such a voltage, the fan can operate stably, ensuring the normal operation of the motor and efficient operation of the fan. A stable voltage input is the foundation for ensuring the stable performance of the wind turbine. The rated voltage of 230V allows the wind turbine to be easily connected to the power supply in most places without the need for additional voltage conversion equipment, improving its versatility and convenience.

 

Size (146 millimeters): The size of the fan is 146 millimeters, which usually refers to the diameter of the fan impeller. The diameter of the impeller has a significant impact on the performance of the fan, and a larger impeller diameter can generally generate greater air volume and pressure. The impeller diameter of 146 millimeters enables D2E146-HT67-01 to provide considerable ventilation while maintaining a compact structure, making it suitable for applications that require space but also high ventilation capacity.

 

Maximum air volume (1060m ³/h): The maximum air volume reaches 1060m³/h, which means that the fan can deliver a large amount of air per unit time. Air volume is a key indicator for measuring the ventilation capacity of a fan. For application scenarios such as ventilation and air exchange in industrial plants and fresh air supply in commercial buildings, sufficient air volume can ensure timely updating of indoor air, provide comfortable air environment for personnel, and also meet the demand for ventilation volume in industrial production processes, eliminating harmful gases and dust.

 

Maximum pressure (460Pa): The maximum pressure is 460Pa, and the pressure parameter reflects the ability of the fan to overcome the resistance of the ventilation duct. In actual ventilation systems, air needs to pass through various pipes, valves, and filters, which all generate a certain amount of resistance. D2E146-HT67-01 has a maximum pressure of 460Pa, which can effectively promote the flow of air in the pipeline, ensuring the normal operation of the ventilation system. Even in situations where the pipeline is long or has high resistance, it can ensure sufficient ventilation effect.

 

Input power (355W): The input power is 355W, which reflects the amount of electricity consumed by the wind turbine during operation. In today's pursuit of high efficiency and energy conservation, power output directly affects operating costs. D2E146-HT67-01 ensures strong ventilation performance while controlling the power at 355W. Compared with some fans of the same type but with higher power, it can save users a lot of electricity expenses and has higher energy utilization efficiency.

 

Rotational speed (2610rpm): The rotational speed is closely related to the air volume and pressure of the fan. Generally speaking, the higher the rotational speed, the greater the air volume and pressure generated by the fan. The speed of 2610rpm enables D2E146-HT67-01 to deliver a large amount of air in a short amount of time and provide sufficient pressure to overcome resistance in the ventilation system. At the same time, a reasonable speed design also ensures the stability and reliability of the fan, avoiding equipment damage and excessive noise caused by excessive speed.

 

Unique design and features

 

Design features of centrifugal fan: D2E146-HT67-01 adopts the design principle of centrifugal fan. Centrifugal fans use the high-speed rotation of the impeller to eject air from the impeller under the action of centrifugal force, thereby obtaining kinetic energy and pressure energy. This design enables the fan to have high efficiency and large air volume. Its blade shape is carefully designed and usually adopts a backward tilting blade. Backward tilting blades can effectively reduce the separation and vortex loss of airflow on the blade surface, improve the efficiency of the fan, and also reduce noise. In addition, the shape and angle of the blades have been optimized to meet the ventilation requirements under different working conditions, ensuring good performance under various working conditions.

 

Motor position and compactness of structure: The motor position of this fan is designed reasonably, usually directly connected to the impeller, reducing transmission components and making the overall structure more compact. This compact structure not only saves installation space, but also reduces the weight and cost of the equipment. At the same time, due to the reduction of transmission components, the operational reliability of the fan has been improved, reducing maintenance costs and the probability of failure. The compact structure advantage of D2E146-HT67-01 can be fully demonstrated in some places with high space requirements, such as the ceiling of commercial buildings or the narrow space of industrial equipment.

 

High efficiency and energy-saving features: As mentioned earlier, D2E146-HT67-01 can achieve a maximum air volume of 1060m ³/h and a maximum pressure of 460Pa with an input power of 355W, demonstrating high energy utilization efficiency. This is thanks to its advanced design and high-quality materials. The impeller of the fan is made of lightweight and high-strength materials, reducing the inertial resistance during rotation and lowering energy consumption. At the same time, the motor adopts an efficient and energy-saving design, which can maintain high efficiency under different loads, further improving the overall energy-saving effect of the fan. Over the long term, the high-efficiency and energy-saving features can save users a significant amount of energy costs.

 

Low noise operation: Although the noise value is not explicitly given, D2E146-HT67-01 has taken a series of measures in its design to reduce noise. In addition to optimizing the blade shape to reduce airflow noise, the casing of the fan also uses sound insulation materials, effectively reducing the noise generated during the operation of the motor and impeller from propagating outward. For some places with high noise requirements, such as offices, hospitals, schools, etc., the low-noise operation characteristics enable the fan to meet the usage requirements of these places without causing interference to personnel's work and life.

 

Summary

 

The D2E146-HT67-01 centrifugal fan, with its excellent parameters and unique characteristics, has demonstrated strong competitiveness in the field of industrial ventilation. Its rated voltage of 230V, size of 146mm, maximum air volume of 1060m ³/h, maximum pressure of 460Pa, input power of 355W, and speed of 2610rpm together form the excellent performance foundation. The design features, compact structure, high efficiency, energy saving, and low-noise operation of centrifugal fans make them stand out among many fan products. Whether it is ventilation in industrial plants, air conditioning in commercial buildings, or other places that require ventilation, D2E146-HT67-01 can play an important role in providing users with efficient, reliable, and energy-saving ventilation solutions. With the continuous development of industrial technology and the increasing demand for ventilation, we believe that D2E146-HT67-01 fan will continue to maintain its advantageous position in the market and contribute to the development of more fields.

 

Small stature and great energy: The outstanding characteristics of D2E146-HT67-01 fan

 

On the big stage of industrial equipment, fans, as key equipment for ventilation and air delivery, have a direct impact on the operational efficiency and stability of the entire system due to their performance. The D2E146-HT67-01 fan under ebm-papst stands out among numerous fan products due to its compact size and powerful functions, becoming a reliable assistant in many industries.

Download
CUSTOMER REVIEWS
5.0 3 Reviews
Write a review
Frequently Bought Together
more
Frequently Bought Together

LATEST NEWS

Ebm - papst D2E146- HT67-01 Centrifugal Fan: Outstanding Features Revealed in Depth

Ebm - papst D2E146- HT67-01 Centrifugal Fan: Outstanding Features Revealed in Depth

Among numerous centrifugal fan products, ebm-papst D2E146-HT67-01 stands out with its outstanding performance and unique features. A deep understanding of these characteristics can help users better understand the advantages and value of the fan, thus fully leveraging its role in practical applications. This article will deeply reveal the outstanding features of the fan.

Feb 17.2025
ebm-papst D2E146 HT67-01 Centrifugal Fan: Analysis of Multiple Application Scenarios

ebm-papst D2E146 HT67-01 Centrifugal Fan: Analysis of Multiple Application Scenarios

In today's society, ventilation and air treatment are indispensable links in various fields. The ebm-papst D2E146-HT67-01 centrifugal fan has been widely used in many fields due to its excellent performance and characteristics. This article will provide an in-depth analysis of the diverse application scenarios of the fan and demonstrate its important role in different industries.

Feb 17.2025
ebm-papst D2E146 HT67-01 Centrifugal Fan: Comprehensive Guide to Operation and Maintenance

ebm-papst D2E146 HT67-01 Centrifugal Fan: Comprehensive Guide to Operation and Maintenance

For the ebm-papst D2E146-HT67-01 centrifugal fan, good operation and maintenance are key to ensuring its long-term stable operation, optimal performance, and extended service life. This article will comprehensively introduce the key points of the fan before operation, during operation, and regular maintenance, providing users with a detailed operation and maintenance guide.

Feb 17.2025
ebm-papst D2E146 HT67-01 Centrifugal Fan: Troubleshooting and Preventive Measures

ebm-papst D2E146 HT67-01 Centrifugal Fan: Troubleshooting and Preventive Measures

Although the ebm-papst D2E146-HT67-01 centrifugal fan has high reliability, various faults may still occur during long-term operation. Understanding the causes, handling methods, and effective preventive measures of common faults is crucial for ensuring the stable operation of fans, reducing downtime, and lowering maintenance costs. This article will elaborate on the common faults, handling methods, and corresponding prevention strategies of the fan.

Feb 17.2025
Breakthrough imagination: unique performance of D2E146-HT67-01 fan

Breakthrough imagination: unique performance of D2E146-HT67-01 fan

The D2E146-HT67-01 fan has a size of only 146 millimeters, making it highly advantageous in terms of space utilization due to its compact exterior design. In modern industrial production, the layout of many equipment is becoming increasingly compact, which imposes strict requirements on the space occupation of supporting equipment

Feb 17.2025
Quick diagnosis: Common faults and solutions of fan D2E146-HT67-01

Quick diagnosis: Common faults and solutions of fan D2E146-HT67-01

Insufficient air volume is one of the common faults of fans. Changes in gas composition may be one reason. When the gas contains a large amount of impurities or viscous substances, it can affect the normal operation of the fan, resulting in a decrease in air volume. Pipeline blockage is also a common factor. After prolonged use, dust and debris may accumulate inside the pipeline, hindering air circulation

Feb 17.2025
Everywhere: The diverse applications of D2E146-HT67-01 fan

Everywhere: The diverse applications of D2E146-HT67-01 fan

In large industrial manufacturing plants, the production process often generates a large amount of heat, harmful gases, and dust. The D2E146-HT67-01 fan, as the core equipment of the ventilation system, can quickly and effectively discharge these polluted air outdoors, while introducing fresh air to maintain good air quality in the factory building

Feb 17.2025
Persistent Protection: Maintenance and upkeep of fan D2E146-HT67-01

Persistent Protection: Maintenance and upkeep of fan D2E146-HT67-01

Daily inspections are the first line of defense for discovering potential problems with fans. During the operation of the fan, carefully listen to its running sound. Under normal circumstances, the D2E146-HT67-01 fan operates with a smooth and regular sound. If there are abnormal friction sounds, impact sounds, or sharp whistling sounds, it may indicate problems such as friction between the impeller and the casing, loose components, or damaged bearings

Feb 17.2025