Before ordering an ebm-papst axial fan, check that the datasheet matches the requested product and the conditions in which it will operate. Read the complete electrical rating, mechanical drawing, connection information and performance conditions together. A diameter or maximum airflow figure alone cannot confirm an order.
APAC FAN supplies W3G800-LV05-03/F01, S6D630-AN01-01 and 4114N/2H6PU. These EC, AC and DC examples show how different parts of a datasheet affect the information you should confirm before purchasing.
Compare the full model on the product record, datasheet and quotation. Retain every letter, hyphen and slash suffix. Keep a copy of the PDF used for the check, including its date or revision where shown, so the quotation can refer to the same information.
W3G800-LV05-03/F01 is made in China and has the same performance as W3G800-LV05-03. The supplied PDF is headed W3G800-LV05-03. Keep W3G800-LV05-03/F01 in the enquiry and purchase order to make the requested supply version clear. This origin and performance statement applies to this specific product; it is not a universal interpretation of /F01 on other fans.
For a replacement, compare the available nameplate and existing purchase record with the proposed item. Record any material number separately if available. A motor code or a document reference should not replace the complete fan designation.
For an AC input, check voltage, phase, frequency and the specified connection together. The S6D630-AN01-01 nominal data contains separate columns for different supply and connection conditions. The following two columns both apply to 400V, three-phase, 50Hz operation.
|
S6D630-AN01-01 nominal data |
Delta connection Δ |
Star connection Y |
|
Speed |
890 rpm |
690 rpm |
|
Power input |
600W |
400W |
|
Current draw |
1.20A |
0.68A |
These are maximum-load nominal figures, not a guarantee of the same values at every point on the airflow curve. Specify the required connection along with the supply conditions; do not combine the speed from one column with the power or current from another.
For 4114N/2H6PU, the nominal supply is 24VDC and the documented voltage range is 16–30VDC. This range describes the permitted supply, not identical performance at every voltage. Review the operating conditions and tolerances attached to the electrical figures before sizing the power supply.
The connection table assigns red to positive supply, blue to ground, violet to PWM and white to the tachometer signal. Before ordering a replacement, compare these functions with the equipment harness and controller. Four wires on another fan do not establish the same assignments or signal requirements.
The PWM input is specified for an open-collector interface, with a frequency range of 1–10kHz and a typical frequency of 2kHz. The tachometer output is also open collector and requires an external resistor. Check the full interface circuit rather than treating the control and feedback wires as additional power leads.
Use the overall assembly drawing and mounting details. Check width or outer diameter, depth, mounting holes, terminal or cable access, and the space needed around the air path. A nominal fan size does not necessarily describe the outside dimensions of the complete assembly.
4114N/2H6PU has a 119*119*38mm body and wired connections. Its dimensions are useful for a compact mounting position, but they do not confirm the mounting pattern, airflow direction or cable routing in the equipment. The connection section also gives a nominal lead length of 310mm; confirm how the leads will reach the intended connection point.
For W3G800-LV05-03/F01, use the assembly drawing in the W3G800-LV05-03 documentation rather than treating the 800mm size as an overall enclosure measurement. Review the housing, guard, depth and mounting interface. Check the delivered assembly against the agreed drawing when the mounting arrangement is critical.
The W3G800-LV05-03 documentation separates the three-phase power connection and protective earth from the control terminals. It also describes RS-485 MODBUS and configurable inputs and outputs. This makes the terminal diagram and parameter settings relevant to the order, as well as the mains rating.
If the equipment requires a particular setpoint, feedback signal or communication arrangement, include that requirement in the enquiry. Ask APAC FAN to confirm the supplied configuration and any required setup. Equal fan performance does not, by itself, document the parameter settings of an individual delivered unit.
Check that the stated airflow and pressure apply to the same operating point, supply and control condition. Maximum free-air flow and maximum static pressure normally describe different ends of a curve; they should not be combined into one required duty point.
For 4114N/2H6PU, the aerodynamic section gives 425m³/h at zero pressure and 860Pa at zero airflow. These values are specified with PWM at 95%, a 2kHz signal and 8400rpm at free air. They are separate endpoints, not a claim that the fan delivers 425m³/h against 860Pa.
The S6D630-AN01-01 PDF includes a chart explicitly titled for 50Hz. Its measured-value table also identifies the connection for each point. Match that chart to a 50Hz requirement; the presence of 60Hz nominal columns elsewhere in the PDF does not turn the 50Hz chart into a 60Hz curve.
Also distinguish nominal data from efficiency reporting. In the S6D630-AN01-01 PDF, 7050m³/h appears in the optimum-efficiency data with 101Pa and 885rpm. It should not be re-labelled as maximum free-air flow or combined with the 690rpm star-connected nominal value.
Operating limits and storage limits serve different purposes. For 4114N/2H6PU, the stated ambient operating range is −20°C to +65°C, while the storage range is −40°C to +80°C. The lower storage temperature does not establish permission to run the fan at that temperature.
Protection ratings also have a defined scope. The 4114N/2H6PU document specifies IP68 for the fan, with qualifications for connections and test conditions. It does not establish that a customer connector or the completed equipment has the same protection. Check the complete installation when moisture exposure is part of the requirement.
The W3G800-LV05-03 documentation distinguishes occasional startup below −25°C from continuous operation in that range, which requires a design with special low-temperature bearings. Include a continuous low-temperature requirement in the enquiry instead of relying only on the minimum temperature in the nominal table.
If a webpage, quotation, nameplate or PDF gives conflicting information, send the relevant records to APAC FAN and identify the field that needs checking. Do not create a specification by taking the preferred value from each source. Ask for the applicable supply details to be confirmed before the order is approved.
Keep a short record of the agreed model, document version, electrical condition and any required configuration. This helps purchasing and engineering review the same item and gives repeat orders a clear reference.
For a known product, send the complete model, quantity, delivery destination and required schedule. Where the order depends on technical details, add the datasheet you reviewed and identify the requirements that must be confirmed.
|
Information |
Include when relevant |
|
Product identity |
Full model, material number if available, and existing label photo. |
|
Electrical requirements |
AC or DC supply; voltage; phase and frequency; required connection. |
|
Mechanical requirements |
Agreed drawing, mounting constraints and connection access. |
|
Performance and controls |
Required airflow at pressure; control signal, feedback and setup requirements. |
|
Operating environment |
Ambient operating range and relevant moisture or exposure conditions. |
APAC FAN can quote for W3G800-LV05-03/F01, S6D630-AN01-01 and 4114N/2H6PU for individual spares, OEM requirements and repeat purchasing. Contact APAC FAN with your product list, or browse our ebm-papst axial fans to locate the relevant product page.
Q1: Does a matching voltage confirm that a fan is suitable?
A1: No. For S6D630-AN01-01, the electrical check includes phase, frequency and star or delta connection. Mechanical fit, performance and the required installation conditions must also match.
Q2: Does W3G800-LV05-03/F01 have different performance from W3G800-LV05-03?
A2: W3G800-LV05-03/F01 is made in China and has the same performance as W3G800-LV05-03. Retain the full /F01 designation in the order to identify the requested supply version.
Q3: Can 4114N/2H6PU deliver its maximum airflow and maximum pressure together?
A3: No. For 4114N/2H6PU, 425m³/h is specified at zero pressure and 860Pa at zero airflow under the documented test conditions. Read the curve for airflow at the required pressure.
Q4: What should I do if the product page and PDF disagree?
A4: Send APAC FAN the complete model, PDF and the conflicting page information. Ask for confirmation of the applicable item and conditions before placing the order.