• Model: W2D300-CP02-31 ebm-papst axial fan
• 300mm industrial axial fan, 400V, 300W
• Airflow 3350m³/h, pressure 125Pa, speed 2750RPM, noise 71dB
• Designed for high-speed industrial ventilation and cooling
• Suitable for HVAC systems, machinery cooling and air circulation
• Reliable performance for continuous heavy-duty operation
Received successfully
Coupon Code
CONTINUE SHOPPING
Quantity:
0 in stock
Save More with Affordable Sea Freight, Talk to Our Experts Today!
Download
  • W2D300-CP02-31 ebm-papst
  • W2D300-CP02-31 ebm-papst
  • W2D300-CP02-31 ebm-papst
  • W2D300-CP02-31 ebm-papst
  • W2D300-CP02-31 ebm-papst
  • W2D300-CP02-31 ebm-papst
1/1
  • W2D300-CP02-31 ebm-papst
  • W2D300-CP02-31 ebm-papst
  • W2D300-CP02-31 ebm-papst
  • Description
Brand: ebmpapst
Part No: W2D300-CP02-31
Fan Type: Axial Fan
Rated Voltage(V): 400
Size(mm): 300
Max.Air Flow(m³/h): 3350
Max.Pressure(Pa): 125
Input Power(W): 300
Speed(rpm): 2750
Noise(db): 71

Download
FAQ
Q1: What is the rated voltage of the ebmpapst W2D300-CP02-31 axial fan, and why is this specification critical for its operation?
A1: The ebmpapst W2D300-CP02-31 axial fan has a rated voltage of 400V. This specification is non-negotiable for safe and efficient operation, as the fan’s internal motor and electrical components are engineered to match this voltage level. Using a power supply lower than 400V will result in insufficient power input, leading to reduced speed, weaker airflow, and potential motor underperformance or overheating from strained operation. Conversely, a higher voltage can overload the motor, damage insulation, or even cause short circuits. For users, this means verifying the power supply matches 400V before installation is essential to avoid equipment failure, extend the fan’s lifespan, and ensure compliance with safety standards.

Q2: What are the max air flow and max pressure of the W2D300-CP02-31 fan, and how do these specs guide its application selection?
A2: The W2D300-CP02-31 axial fan delivers a max air flow of 3350 m³/h and a max pressure of 125 Pa. These two specs work together to define its ideal use cases: the 3350 m³/h airflow ensures it can circulate large volumes of air, while the 125 Pa pressure allows it to push air through systems with moderate resistance—such as enclosed industrial control cabinets, medium-sized HVAC ductwork, or cooling setups for machinery with partial airflow obstructions. Unlike fans with lower pressure, it won’t struggle to maintain airflow in slightly restricted spaces; unlike high-pressure fans, it avoids unnecessary energy consumption for simple, open-area cooling. This balance makes it perfect for industrial equipment that needs consistent, unobstructed air circulation with minor system resistance.

Q3: What are the input power and speed of the ebmpapst W2D300-CP02-31, and how do these two specs relate to its performance and energy efficiency?
A3: The ebmpapst W2D300-CP02-31 has an input power of 300W and a speed of 2750 rpm. These two specs are closely linked to its performance and energy efficiency: the 2750 rpm speed is calibrated to generate the fan’s 3350 m³/h max airflow, ensuring it delivers sufficient air movement without excessive rotation (which would increase noise and wear). The 300W input power, meanwhile, reflects the energy needed to sustain this speed—striking a balance between performance and efficiency. Compared to higher-power fans with similar speed, it uses less energy for daily operation, reducing long-term electricity costs. For users, this means they get reliable airflow (from the 2750 rpm speed) without overspending on energy (thanks to the 300W power draw), making it a cost-effective choice for continuous-use scenarios like 24/7 industrial cooling.

Q4: What is the noise level of the W2D300-CP02-31 axial fan, and how does this impact its suitability for different environments?
A4: The ebmpapst W2D300-CP02-31 axial fan has a noise level of 71 dB. To put this in context, 71 dB is similar to the sound of a busy office printer or moderate traffic from a nearby street—not overly loud, but not quiet either. This noise level makes it well-suited for industrial environments like manufacturing workshops, mechanical rooms, or warehouse cooling systems, where background noise is already present and the fan’s sound won’t disrupt operations. However, it’s less ideal for noise-sensitive spaces such as offices, residential areas, or labs requiring low ambient sound, as its 71 dB output could cause distraction or discomfort. For users planning installation, assessing the target environment’s noise tolerance is key—if quiet operation is needed, additional sound dampening measures (like acoustic enclosures) may be required, but for industrial settings, the noise level is within acceptable limits.

Q5: What is the size of the ebmpapst W2D300-CP02-31 fan, and what practical considerations does this create for installation and system compatibility?
A5: The ebmpapst W2D300-CP02-31 axial fan has a size of 300mm, which refers to its primary dimension (typically the diameter of the fan housing or blade assembly). This size creates two key practical considerations for installation and compatibility. First, users must ensure the installation space has enough physical room to fit the 300mm fan—this includes checking not just width/diameter, but also clearance around the fan (especially for airflow). Blocked clearance (e.g., tight gaps against walls or other equipment) can disrupt air intake/exhaust, reducing the fan’s efficiency and causing overheating. Second, the 300mm size must align with the system it’s integrated into—for example, if replacing an old fan, the new 300mm model should match the existing mounting holes or duct openings to avoid costly modifications. For new systems, designers need to account for the 300mm size when planning enclosure dimensions or duct sizing, ensuring the fan fits seamlessly and operates at peak performance.