W2E143-AB09-01 ebm-papst

No.W2E143-AB09-01
SKU:
5.0 (4)
78 Sold
$42.38 $0.00
• Model: W2E143-AB09-01 ebm-papst axial fan
• 172×51mm compact AC fan, 230V, 24W low power
• Airflow 420m³/h, pressure 65Pa, speed 2800RPM
• Designed for compact ventilation and electronics cooling
• Suitable for HVAC systems, control cabinets and devices
• Reliable airflow solution for space-limited applications
Received successfully
Coupon Code
CONTINUE SHOPPING
Quantity:
0 in stock
Save More with Affordable Sea Freight, Talk to Our Experts Today!
Download
  • W2E143-AB09-01 ebm-papst
  • W2E143-AB09-01 ebm-papst
  • W2E143-AB09-01 ebm-papst
  • W2E143-AB09-01 ebm-papst
  • W2E143-AB09-01 ebm-papst
  • W2E143-AB09-01 ebm-papst
1/1
  • W2E143-AB09-01 ebm-papst
  • W2E143-AB09-01 ebm-papst
  • W2E143-AB09-01 ebm-papst
  • Description
  • Detailed Information
Brand: ebm-papst
Part No: W2E143-AB09-01
Fan Type: Axial Fan
Rated Voltage(V): 230
Size(mm): 172φ*51
Max.Air Flow(m³/h): 420
Max.Pressure(Pa): 65
Input Power(W): 24
Speed(rpm): 2800
Noise(dB): N/A
Mass: 0.91 kg
Surface of Rotor: Rotor open, coated in black
Material of Blades: Sheet steel, coated in black
Material of Wall Ring: Die-cast aluminium, coated in black
Number of Blades: 5
Direction of Air Flow: "V"
Direction of Rotation: Counter-clockwise, seen on rotor
Type of Protection: IP 20
Insulation Class: "B"
Max. Permissible Ambient Motor Temp. (Transp./ Storage): + 80℃
Min. Permissible Ambient Motor Temp. (Transp./Storage): - 40℃
Mounting Position: Any
Condensate Discharge Holes: None, open rotor
Operation Mode: S1
Motor Bearing: Ball bearing
Leakage Current: < 0.75 mA
Electrical Leads: With plug
Motor Protection: Thermal overload protector (TOP) wired internally
Protection Class: I (if earth wire is connected by customer)
Product Conforming to Standard: EN 60335-1; CE
Approval: CSA C22.2 Nr.113; VDE; UL 507; CCC; GOST


ebm-papst W2E143-AB09-01: The Energy-Efficient Axial Fan Optimizing Data Center Thermal Performance

 

In the fast-paced world of data centers, where every watt of energy and every millimeter of space matters, the search for cooling solutions that balance performance, efficiency, and adaptability never stops. The ebm-papst W2E143-AB09-01 axial fan emerges as a standout choice, engineered specifically to meet the nuanced demands of modern data center environments. As a product of ebm-papst—an industry leader with decades of expertise in air movement technology—this fan combines sleek design, impressive airflow, and energy-conscious engineering, making it a reliable workhorse for keeping critical IT infrastructure cool, efficient, and operational.

 

At its core, the W2E143-AB09-01 is built to deliver powerful cooling without sacrificing energy efficiency—a top priority for data centers, which face mounting pressure to reduce carbon footprints and operational costs. Operating at a rated voltage of 230V, the fan seamlessly integrates with the standard electrical systems of most commercial and industrial data centers, eliminating the need for costly power adapters or infrastructure overhauls. What sets it apart, however, is its remarkable energy efficiency: with an input power of just 24W, it consumes far less energy than many comparable cooling solutions while still delivering a maximum airflow of 420 m³/h. This translates to significant long-term savings for data center operators, who can cut electricity expenses without compromising on cooling capacity.

 

Complementing its high airflow is a maximum pressure of 65 Pa—enough to push cool air through the dense arrays of servers, cables, and air filters common in data center racks. This pressure ensures that airflow remains consistent even in high-density setups, preventing the formation of hotspots that can cause server throttling or hardware failure. Paired with a rotational speed of 2800 rpm, the fan’s airflow and pressure work in tandem to maintain uniform temperatures across server racks, a critical factor for preserving the performance and lifespan of sensitive IT equipment.

 

The W2E143-AB09-01’s physical design and material selection further enhance its suitability for data center use. Measuring 172φ×51 mm and weighing just 0.91 kg, it boasts a compact, lightweight form factor that fits effortlessly into tight spaces—whether mounted in rack enclosures, in-row cooling units, or overhead duct systems. This versatility is a boon for data center designers, who often need to optimize space in facilities where every square inch is valuable.

 

Durability is another key strength of the fan’s construction. Its blades are crafted from sheet steel coated in black, a material choice that balances strength and corrosion resistance. Sheet steel withstands the constant vibration and wear of 24/7 operation, while the black coating protects against dust and environmental contaminants—common in data centers—that can degrade fan performance over time. The wall ring, made from die-cast aluminium (also coated in black), adds structural rigidity, ensuring the fan remains stable even during prolonged use. The open rotor design (with a black-coated surface) further supports durability by reducing the risk of debris buildup, while the absence of condensate discharge holes simplifies maintenance and eliminates the need for additional drainage systems.

 

Reliability is non-negotiable in data centers, where even brief cooling interruptions can lead to costly downtime. The W2E143-AB09-01 is engineered to deliver consistent performance, starting with its ball bearing motor. Ball bearings reduce friction compared to sleeve bearings, extending the fan’s lifespan and ensuring smooth operation for tens of thousands of hours—critical for fans that run continuously. The fan’s insulation class “B” rating provides thermal protection, allowing it to operate safely in the warm ambient temperatures of data center hot aisles, while its IP 20 protection rating shields internal components from dust and large debris.

 

Safety is further reinforced by built-in features like the thermal overload protector (TOP), which is wired internally to shut down the fan if it overheats—preventing motor damage and reducing fire risks. A leakage current of less than 0.75 mA also enhances electrical safety, protecting maintenance staff and data center infrastructure from potential hazards. Additionally, the fan’s “any mounting position” flexibility ensures it can be installed in vertical, horizontal, or angled orientations, adapting to the unique layout needs of different data center designs.

 

The W2E143-AB09-01’s compliance with global standards and certifications adds another layer of value for data center operators. It meets the EN 60335-1 standard for electrical safety (and carries the CE mark) and holds approvals from leading global bodies, including CSA C22.2 Nr.113 (Canada), VDE (Germany), UL 507 (United States), CCC (China), and GOST (Russia). This means the fan can be deployed in data centers worldwide, ensuring consistent performance and adherence to local safety regulations—an essential feature for multinational data center networks.

Practical usability is also prioritized in the fan’s design. It comes with pre-installed electrical leads and a plug, simplifying installation and reducing setup time. The “V” direction of air flow is optimized for typical data center airflow patterns, ensuring the fan works in harmony with other cooling components (such as air handlers and chillers) to maximize heat dissipation. Its S1 operation mode (continuous duty) confirms it can run 24/7 without overheating, aligning with the non-stop operational demands of data centers.

 

In real-world data center applications, the W2E143-AB09-01 excels in scenarios where efficiency and space are at a premium. For example, in mid-sized data centers with moderate server density, it provides targeted cooling for individual racks, ensuring each server receives adequate airflow. In edge data centers—compact facilities located close to end-users—it fits into limited space while delivering the cooling power needed for localized IT equipment. Its low energy consumption also makes it ideal for green data centers, where sustainability is a core objective.

 

Backed by ebm-papst’s global support network, the W2E143-AB09-01 comes with comprehensive technical documentation, including installation guides and performance curves, to help operators optimize its integration. ebm-papst’s worldwide service centers also ensure that any maintenance or troubleshooting needs are addressed quickly, minimizing downtime.

 

In conclusion, the ebm-papst W2E143-AB09-01 axial fan is a versatile, efficient, and reliable solution tailored to the evolving needs of modern data centers. Its combination of high airflow, low energy consumption, durable construction, and global compliance makes it an ideal choice for operators seeking to balance performance, cost savings, and sustainability. As data centers continue to grow in complexity and density, the W2E143-AB09-01 stands as a testament to ebm-papst’s commitment to innovation—and a trusted partner in keeping critical data center infrastructure cool and efficient.

CUSTOMER REVIEWS
5.0 4 Reviews
Write a review
Frequently Bought Together
more
Frequently Bought Together
Download

New Arrivals